Custom Cartridge
heaters, Heaters, cartridge, cartuchos,
watlow, chromalox, resistencias, Resistencias Cartuchos.
 |
 |
 |
  |
 |
| |
|
|
|

|
|
Maximum Allowable Watt Density for
Heating Metals
|
|
Block Temperature in ° F
|
|
|
1200
|
1000
|
800
|
600
|
400
|
200
|
|
Clearance
|
0.002
|
140
|
270
|
300
|
300
|
300
|
300
|
|
0.003
|
120
|
205
|
295
|
300
|
300
|
300
|
|
0.004
|
100
|
175
|
240
|
300
|
300
|
300
|
|
0.005
|
90
|
145
|
200
|
285
|
300
|
300
|
|
0.007
|
70
|
100
|
150
|
300
|
250
|
300
|
|
0.010
|
60
|
90
|
110
|
150
|
200
|
225
|
|
0.015
|
50
|
75
|
95
|
110
|
140
|
165
|
|
0.030
|
40
|
60
|
80
|
90
|
100
|
110
|
|
0.060
|
30
|
40
|
50
|
55
|
65
|
65
|
|
0.100
|
25
|
35
|
45
|
50
|
50
|
50
|
-


|
Maximum Cartridge Watt Density
in Still Air
|
| Air Temperature ° F |
100
|
250
|
500
|
750
|
1000
|
1100
|
1200
|
1300
|
1400
|
|
Max Watts in2
|
53
|
52
|
50
|
46
|
40
|
35
|
28
|
20
|
13
|

|
Maximum Cartridge Watt Density in Moving Air
|
| |
Air Velocity, Feet per Minute
|
|
Air Direction
|
0
|
500
|
1000
|
1500
|
2000
|
2500
|
3000
|
3500
|
4000
|
|
Parallel to Heater
|
44
|
52
|
56
|
60
|
64
|
67
|
72
|
75
|
78
|
|
Perpendicular to Heater
|
44
|
68
|
76
|
82
|
86
|
93
|
97
|
103
|
108
|

|
Cartridge
Temperature in 70°F Air
|
| |
Watt Density
|
| |
5
|
10
|
15
|
20
|
25
|
30
|
35
|
40
|
|
Oxidized Sheath
|
450
|
800
|
1050
|
1100
|
1200
|
1300
|
1350
|
1400
|
|
Non-Oxidized Sheath
|
750
|
1000
|
1150
|
1300
|
1400
|
1500
|
1600
|
1650
|

Cartridge are UL recognized, File
#E202904
and CSA certified, CSA file no. LR 109455-1
|
|
- FC Service Inc.
- P.O.Box 27740
- Las Vegas, NV
89126
- Tel:
702-837-7404
- Fax:
702-507-0053
- Toll Free:
877-292-7509
|
|
 |
|
|
       |
|
  |
|
|
|
|
 |
 |
 |
 |
 |